Holter Monitor Billing services
Specialty Billing

Holter and Event Monitor Billing: CPT 93224 to 93272

Holter monitor CPT codes 93224 to 93227, extended 93241 to 93248, event 93268 to 93272 and 93228 to 93229, with Florida Medicare rules for 24 and 48 hour.

Trusted by Healthcare Practices
Multi-Specialty Billing Experience
Dedicated Billing & RCM Teams
Quick Summary

Holter and event monitor codes in brief

A Holter monitor is reported with CPT 93224 to 93227 for continuous external ECG recording up to 48 hours, so 24 hour and 48 hour studies use the same code family. Longer patch monitoring is 93241 to 93248, event recorders are 93268 to 93272, and mobile cardiac telemetry is 93228 and 93229.

  • 93224 is the global Holter code; 93225, 93226 and 93227 are its recording, scanning and physician review parts.
  • Extended external monitors are 93241 to 93244 for up to 7 days and 93245 to 93248 for up to 15 days.
  • Patient-activated event recorders are 93268 to 93272, and mobile cardiac telemetry is 93228 and 93229, once per 30 days.
  • First Coast LCD L39492 and article A59270 set Florida Medicare coverage, documentation and diagnosis rules.

Holter Monitor Billing Explained

The CPT code for a Holter monitor is 93224 for the complete service, with 93225, 93226 and 93227 as its components, and it covers continuous external ECG recording for up to 48 hours. There is no separate code for a 24 hour Holter and a 48 hour Holter. Monitors worn longer, triggered by the patient or analyzed in real time use different code families, so the first billing task is matching the device to the right family.

Medsure RCS handles ambulatory monitoring charges for cardiology groups as part of its cardiology medical billing service. This page lays out each monitor family, the professional and technical splits, and the Florida Medicare policy that decides coverage. For the neighboring tests, see our pages on stress test coding, EKG coding, echocardiogram billing and the wider cardiology CPT codes. CPT descriptors belong to the American Medical Association, so each code below is described in plain words.

Holter Monitor Billing detail view

What Are the Holter Monitor CPT Codes?

  • 93224: external ECG recording up to 48 hours, the complete service with recording, scanning analysis and physician review.
  • 93225: the recording component only, the hookup and data capture.
  • 93226: the scanning analysis component only, with report.
  • 93227: the physician review and interpretation component only.
  • In the 2026 CMS Physician Fee Schedule (PFS) file all four codes have status A, so they are paid separately when covered.

How Are 24 Hour and 48 Hour Holter Monitors Billed?

A 24 hour Holter and a 48 hour Holter are both reported with 93224 to 93227. First Coast Service Options groups external Holter monitoring as continuous recording for up to 48 hours under that single code family in its billing article A59270, so the number of hours worn within that range does not change the code. What changes the code is the wear time and monitor type. If the device records for more than 48 hours, the extended codes 93241 to 93248 apply. If the patient triggers the recording, an event code applies. The First Coast LCD also says a 24 to 48 hour monitor is most appropriate for patients with daily or near-daily symptoms, and that monitoring duration should match the patient's signs and symptoms.

How Do Holter, Event and Patch Monitor Billing Differ?

  • Holter, up to 48 hours of continuous recording: 93224 to 93227.
  • Extended external ECG, more than 48 hours up to 7 days: 93241 to 93244.
  • Extended external ECG, more than 7 days up to 15 days: 93245 to 93248.
  • Patient-activated or auto-activated event monitor with symptom-triggered memory loop and remote download, or 24 hour attended monitoring, worn up to 30 days: 93268 to 93272.
  • Mobile cardiovascular telemetry with real-time analysis and attended remote surveillance, worn up to 30 days: 93228 and 93229.
  • External ECG for more than 15 days up to 30 days: Category III codes 0937T to 0940T, which the 2026 PFS lists with status C, meaning the MAC prices the code.
  • Implanted subcutaneous cardiac rhythm monitor: 93298.
  • The wear time ranges above come from the table in First Coast billing article A59270. Payers other than Medicare may define patch devices and these ranges differently, so check each plan's policy.

When Are Extended ECG Monitoring Codes 93241 to 93248 Used?

Extended monitoring is reported with 93241 to 93244 for more than 48 hours up to 7 days, and 93245 to 93248 for more than 7 days up to 15 days. Each range has a global code and component codes for recording, scanning analysis and physician review. In the 2026 PFS file, 93241 and 93245 are the global codes, with PC/TC indicator 4. For the shorter range, 93242 is the recording, 93243 is the scanning analysis with report and 93244 is the physician review and interpretation. For the longer range, 93246 is the recording, 93247 is the scanning analysis and 93248 is the physician review and interpretation. Bill only the components your practice actually performed.

How Is an Event Recorder Billed With 93268 to 93272?

Patient-activated and auto-activated event recorders are reported with 93268 for the global service or with the components 93270, 93271 and 93272. First Coast describes this family as monitors with a symptom-related memory loop and remote download capability, or 24 hour attended monitoring, worn for up to 30 days. In the 2026 PFS file, 93268 has PC/TC indicator 4. The component codes are 93270 and 93271, the technical parts covering the recording and the monitoring analysis, both with indicator 3, and 93272, the physician review and interpretation, with indicator 2. The First Coast documentation rules for attended monitoring ask that rhythm strip transmissions record the patient's name, presenting diagnosis, transmission date and time, channel, rate, rhythm, PR and QRS intervals when abnormal, reported symptoms and any action taken.

How Is Mobile Cardiac Telemetry Billed With 93228 and 93229?

Mobile cardiovascular telemetry is reported with 93228 for the physician review and report and 93229 for the technical service, and First Coast says both are reported once per 30 days. The article A59270 describes this monitor as real-time analysis with attended remote surveillance, worn up to 30 days. In the 2026 PFS file, 93228 carries PC/TC indicator 2, professional only, and 93229 carries indicator 3, technical only, so the two are billed by whoever performed each part and neither takes modifier 26 or TC. The LCD adds that mobile telemetry is not reasonable and necessary when the 24 hour monitoring station does not meet its definition: a facility operating around the clock with a receiving station staffed by non-physician personnel and immediate access to a physician for out-of-range data.

How Do Professional and Technical Components Apply to Monitor Codes?

Ambulatory ECG codes are split by component codes, not by modifiers 26 and TC. CMS states that modifiers 26 and TC cannot be used with PC/TC indicators 2, 3 or 4, and every monitor code family above uses those indicators. The 2026 PFS file shows how the parts are divided. The global codes 93224, 93241, 93245 and 93268 have indicator 4. The physician review codes 93227, 93244, 93248 and 93272 have indicator 2 and carry the work RVUs. The recording and analysis codes have indicator 3 and carry practice expense. A cardiology practice that buys a monitoring service from an outside vendor and only reviews the final report bills the physician review code, while the vendor bills the technical codes. The global code includes the technical work, so it should not be billed when another entity performed that work. See modifier 26 and modifier TC for the codes that do use those modifiers. Rhythm ECG codes 93040 to 93042 are not used to report cardiac rhythm monitoring. NCCI Policy Manual Chapter 11 states they describe diagnostic rhythm ECG testing and shall not be reported for cardiac rhythm monitoring in any site of service. A Holter, patch or event monitor claim built on 93040 is a coding error. See EKG coding for the resting and rhythm ECG codes.

What Are the First Coast Medicare Rules for Ambulatory ECG Monitoring?

Florida Medicare covers ambulatory ECG monitoring under First Coast Service Options LCD L39492, Ambulatory Electrocardiograph (AECG) Monitoring, with billing article A59270. The LCD took effect for services on or after June 11, 2023, after claims analysis showed what First Coast called aberrant utilization of cardiac monitoring services. It applies in Florida, Puerto Rico and the U.S. Virgin Islands. The LCD says monitoring is reasonable and necessary only with an FDA-cleared device and for listed reasons. These include cardiac complaints not explained by a 12-lead ECG, history and exam, unexplained syncope, near syncope, dizziness, chest pain, palpitations or shortness of breath, documented or suspected bradycardia, nocturnal arrhythmias, rate control in atrial fibrillation, antiarrhythmic drug dosing, assessing arrhythmia therapy such as post-ablation, and occult atrial fibrillation as a possible cause of cryptogenic stroke. Devices without FDA clearance, including smartphone and hand-held devices, are not covered. Article A59270 lists ICD-10-CM codes that support medical necessity, and codes not on the list do not support it. The record must show a diagnosis or clinical suspicion of a cardiac event, must support the need for monitoring beyond 24 hours and the specific monitor type, and should document symptoms such as syncope, dizziness, shortness of breath, chest discomfort or palpitations, abnormal test results or relevant cardiac history. It must also include the interpretation and the name of the interpreting physician. The article's current revision shows an effective date of October 1, 2026, so confirm the diagnosis list on the CMS Medicare Coverage Database before each submission cycle. See our Medicare billing page for the wider rules and the cardiology ICD-10 codes guide for diagnosis code families.

What Are the Most Common Cardiac Monitor Billing Errors?

  • Billing a Holter code for a device worn longer than 48 hours instead of 93241 to 93248.
  • Billing the global code, such as 93224 or 93268, when a vendor performed the recording or analysis.
  • Reporting 93228 or 93229 more than once in a 30 day period.
  • Using 93040 to 93042 for rhythm monitoring.
  • Linking a diagnosis that is not on the First Coast A59270 list.
  • Missing documentation of symptoms, the monitor type and why monitoring beyond 24 hours was needed.
  • Using a device without FDA clearance, which the LCD does not cover.

Holter Monitor Billing, Frequently Asked Questions

The CPT code for a Holter monitor is 93224 for the complete service. The components are 93225 for recording, 93226 for scanning analysis with report and 93227 for physician review and interpretation. The family covers continuous recording up to 48 hours.

A 24 hour Holter uses the same codes as a 48 hour Holter, 93224 to 93227. The family covers continuous external ECG recording up to 48 hours, so there is no separate 24 hour code. If the monitor is worn longer than 48 hours, use 93241 to 93248.

A 48 hour Holter is reported with 93224 as the global code, or with 93225, 93226 and 93227 when different providers perform the parts. Recording longer than 48 hours moves the claim into the extended monitoring codes 93241 to 93248.

A Holter records continuously for up to 48 hours and is billed with 93224 to 93227. An event monitor records when the patient or the device triggers it and may be worn up to 30 days, billed with 93268 to 93272. Mobile cardiac telemetry, 93228 and 93229, adds real-time analysis with remote attended monitoring.

No. Holter, extended, event and telemetry codes are split by component codes instead of modifiers. CMS says modifiers 26 and TC cannot be used with the PC/TC indicators these codes carry, so report 93225 and 93226 for the technical parts and 93227 for the physician review.

Codes 93228 and 93229 are reported once per 30 days under First Coast billing article A59270. The monitoring station must also meet the 24 hour monitoring station definition in LCD L39492.

Back to the list of questions

Ask About Holter Monitor Billing

Ready to Improve Your Holter Monitor Billing?

Talk to a Medsure RCS specialist. No commitment, no pressure, just answers.

Newsletter

Sign up for our newsletter to receive updates, industry news, and articles about medical billing and revenue cycle management.